Parker · TW · DESICCANT · HEATLESS

TW201

200 SCFM · -40°F dew point · 15% purge · 150 PSI max
PRICE
Unverified
no price source on file
Parker TW201

Parker TW201 is a heatless desiccant compressed-air dryer rated at 200 SCFM at standard inlet conditions, delivering a -40°F pressure dew point. Maximum inlet pressure is 150 PSI. The unit connects via 1-1/2 NPT port. Voltage is rated at 120–240V / 60 Hz / single-phase for electrical flexibility across facility power configurations. The TW201 uses dual-tower pressure-swing adsorption to achieve ISO 8573-1 Class 2 moisture performance, suitable for larger industrial systems requiring critical moisture protection in instrumentation air, electronics manufacturing, pharmaceutical processing, and food-grade compressed-air applications. Heatless desiccant designs consume approximately 15–18% of dried output air for tower regeneration — account for purge loss in system sizing. Parker Hannifin publishes an OEM brochure for the TW series at parker.com confirming flow and dewpoint specifications. Pricing is available through authorized Parker distributors.

Flow
200 SCFM
Dew point
-40 °F
Purge loss
15 %
Max PSI
150 PSI
Air output per kW inputNo flow/power on file
SCFM/kW
Poor 35Typical 60Good 90
Pressure dew pointClass typical · desiccant · heatless
-40°F
Warmer +30°Class typ -40°FDrier −30°
Price per cubic foot · minuteNo price source on file
$/SCFM
Good $180Typical $280High $420
PERFORMANCE
Catalog flow200 SCFM @ 150 PSI
Pressure dew point-40°F
Purge loss15%
Rating conditions100 psig / 100°F inlet / 100°F ambient
Regen cycle10-minute NEMA cycle
Best fitCritical-process drying to −40°F dew point
INLET & OPERATING CONDITIONS
Inlet PSI range80–150 PSI
Max inlet temp120°F
Connections1-1/2″ NPT
ELECTRICAL & FORM
Electrical service120-240V 60Hz 1-Ph
Weight692 lb
Dimensions81 H x 42 W x 34 D in
COST & OWNERSHIP
Yearly estimates assume 8 hr/day · 250 day/yr at $0.13/kWh. Adjust to your shop’s actual utilization for a precise number.
Purge cost · yearlyEst. $1,800
Brochureview · download PDF

Where this sits in the catalog

Compared against 25 other desiccant · heatless dryers in the catalog.

  • Flow capacity200scfm
    6 scfmmedian 113.5 scfm1,500 scfm
    +76.2% vs. median
  • Pressure dew point-40°F
    -40°Fmedian -40°F-5°F
    0°F vs. median
  • Purge loss15%
    15%median 15%18.5%
    0 pts vs. median
Where this is soldPricing pending verification